With MELAcare and Careclave, MELAG offers two innovative solutions for the reprocessing and maintenance of hollow-body dental instruments between treatments. The key difference lies in their intended use: MELAcare complements existing autoclaves as a compact, specialised solution for cleaning, disinfection and maintenance of, for example, handpieces and contra-angles, turbines, ultrasonic tips and prophylaxis handpieces. Careclave, on the other hand, is a globally unique 4-in-1 system solution that combines the entire reprocessing process – comprising cleaning, disinfection, maintenance and even sterilisation – in a single unit. Which solution is more suitable depends on the requirements of your dental practice, oral and maxillofacial surgery practice or orthodontic practice – from the daily volume of instruments to the space available in the reprocessing room.
MELAcare: The perfect complement to the MELAG autoclave
MELAcare is particularly suitable for dental practices that wish to clean, disinfect and – depending on the lid used – also maintain their transmission instruments fully automatically within a small footprint. With compact dimensions of 31 × 44 × 38 cm, this reprocessing and maintenance unit is of particular interest to those modernising their practice or taking over an existing one, who already have an autoclave and wish to specifically supplement their existing processes. A separate autoclave is still required for the subsequent sterilisation of critical instruments. Overall, therefore, a worktop width of at least 85 cm should be allowed for the MELAcare and the autoclave.
Depending on the type of instrument, two specialised lids are available. The MELAcare Blue lid cleans, disinfects and maintains up to six handpieces, contra-angles, turbines or contra-angle heads in just 17 minutes. The Green lid is designed for up to six ZEG tips with torque wrenches, ultrasonic handpieces, Sprayvit nozzles or prophylaxis handpieces, and completes cleaning and disinfection within 14 minutes. MELAcare automatically recognises the lid used and suggests the appropriate programme, thereby simplifying operation and supporting a systematic workflow.
Cleaning is carried out using ULTRAflow technology. This involves passing compressed-air-accelerated, fully demineralised water through the instruments – entirely without the use of process chemicals. The instruments are then thermally disinfected at approximately 95 °C and an A0 value of 3,000. With the Blue lid, oil maintenance of the gear channels in rotating instruments is also carried out. Finally, the spray and drive channels are flushed with compressed air, dried and gently cooled. Collet maintenance can be carried out independently of the reprocessing cycle via the integrated maintenance station. Documentation and release are carried out directly on the large Smart-Touch display, as well as via the network or USB.
Thanks to its short cycle times, MELAcare is specifically designed for reprocessing between treatments. Up to 144 instruments can be reprocessed per working day. With the intelligent additional cooling system, they are ready for use again just five minutes after the end of the process. This makes MELAcare an efficient addition to existing reprocessing set-ups, particularly for practices with a high volume of instruments – especially where proven individual solutions, fast processing times and high availability are key priorities.