XXL Washer-Disinfector: Discover MELAtherm 20 >

Products Service Discover Contact
  • System Solution
  • Bestsellers Australia
  • Autoclaves
  • Large Autoclaves
  • Small autoclaves
  • Washer-Disinfectors
  • Ultrasonic cleaners
  • Sealing Devices
  • Packaging
  • Documentation
  • MELAverse
  • Care
  • Water Treatment
  • Routine Testing
  • Consumables
  • Bestsellers Australia
    Bestsellers Australia
  • Autoclaves
    Autoclaves
  • Large Autoclaves
    Large Autoclaves
  • Small autoclaves
    Small autoclaves
  • Washer-Disinfectors
    Washer-Disinfectors
  • Ultrasonic cleaners
    Ultrasonic cleaners
  • Sealing Devices
    Sealing Devices
  • Packaging
    Packaging
  • Documentation
    Documentation
  • MELAverse
    MELAverse
  • Care
    Care
  • Water Treatment
    Water Treatment
  • Routine Testing
    Routine Testing
  • Consumables
    Consumables
Bestsellers Australia
Bestsellers Australia
  • Premium Class
    Premium Class
  • Prime Line (Class B)
    Prime Line (Class B)
  • Pro Line (Class B)
    Pro Line (Class B)
  • Pro Line (Class S)
    Pro Line (Class S)
  • Vacuclave 105 / 305
    Vacuclave 105 / 305
  • Vacuclave 550
    Vacuclave 550
  • Cliniclave 45 Series
    Cliniclave 45 Series
  • Vacuklav 24 BL+
    Vacuklav 24 BL+
  • Accessories & components for autoclaves
    Accessories & components for autoclaves
  • Cliniclave 45
    Cliniclave 45
  • Cliniclave 45 M
    Cliniclave 45 M
  • Cliniclave 45 D
    Cliniclave 45 D
  • Cliniclave 45 MD
    Cliniclave 45 MD
  • Vacuclave 550
    Vacuclave 550
  • Accessories & components for large autoclaves
    Accessories & components for large autoclaves
  • Vacuclave 105
    Vacuclave 105
  • Vacuclave 305
    Vacuclave 305
  • MELAtherm 20
    MELAtherm 20
  • MELAtherm 10 Evolution
    MELAtherm 10 Evolution
  • Ultrasonic cleaners
    Ultrasonic cleaners
  • Loading patterns
    Loading patterns
  • Baskets & Adapters
    Baskets & Adapters
  • MELAcontrol Wash Check
    MELAcontrol Wash Check
  • Regenerating Salt
    Regenerating Salt
  • Accessories & components for thermal disinfectors
    Accessories & components for thermal disinfectors
Ultrasonic cleaners
Ultrasonic cleaners
  • MELAseal 300
    MELAseal 300
  • MELAseal 200
    MELAseal 200
  • MELAseal 100+
    MELAseal 100+
  • Routine Testing
    Routine Testing
  • Accessories & components for sealing devices
    Accessories & components for sealing devices
  • MELAstore Trays
    MELAstore Trays
  • MELAstore Tray Ophthalmology
    MELAstore Tray Ophthalmology
  • MELAstore Boxes
    MELAstore Boxes
  • MELAstore transport box
    MELAstore transport box
  • Accessories & components for sterile goods storage
    Accessories & components for sterile goods storage
  • MELAtrace
    MELAtrace
  • MELAverse
    MELAverse
  • MELAprint 80
    MELAprint 80
  • MELAprint 60
    MELAprint 60
  • MELAdoc
    MELAdoc
  • MELAflash
    MELAflash
  • MELAnet Box
    MELAnet Box
  • Accessories & components for documentation
    Accessories & components for documentation
MELAverse
MELAverse
  • Care Oil Spray
    Care Oil Spray
  • Chamber Protect
    Chamber Protect
  • MELAdem 40
    MELAdem 40
  • MELAdem 47
    MELAdem 47
  • MELAdem 53
    MELAdem 53
  • MELAdem 53 C
    MELAdem 53 C
  • MELAdem 56
    MELAdem 56
  • MELAjet
    MELAjet
  • Accessories & components for water treatment
    Accessories & components for water treatment
  • MELAcontrol Wash Check
    MELAcontrol Wash Check
  • MELAcontrol Seal Check
    MELAcontrol Seal Check
  • MELAcontrol Ink Test
    MELAcontrol Ink Test
Consumables
Consumables
  • MELAG Service World
  • Downloadcenter
  • Troubleshooting
  • Video Tutorials
  • Device Registration
  • Service Portal
  • Technical Training
  • Configurator
  • Downloadcenter
    Downloadcenter
  • Troubleshooting
    Troubleshooting
  • Video Tutorials
    Video Tutorials
  • Device Registration
    Device Registration
  • Service Portal
    Service Portal
  • Technical Training
    Technical Training
  • Configurator
    Configurator
Downloadcenter
Downloadcenter
Troubleshooting
Troubleshooting
  • MELAcare Tutorials
    MELAcare Tutorials
  • Careclave Tutorials
    Careclave Tutorials
  • Autoclaves Tutorials
    Autoclaves Tutorials
  • Washer-Disinfector Tutorials
    Washer-Disinfector Tutorials
  • MELAseal 200 Tutorials
    MELAseal 200 Tutorials
  • MELAseal 300 Tutorials
    MELAseal 300 Tutorials
  • MELAtrace Tutorials
    MELAtrace Tutorials
Device Registration
Device Registration
Service Portal
Service Portal
Technical Training
Technical Training
Configurator
Configurator
  • Promotions
    Promotions
  • Success Stories
    Success Stories
  • Inspiration & Tips
    Inspiration & Tips
  • News
    News
  • Family Business & Jobs
    Family Business & Jobs
Promotions
Promotions
Success Stories
Success Stories
Inspiration & Tips
Inspiration & Tips
News
News
Family Business & Jobs
Family Business & Jobs
  • Book a consultation: On-site, online or in a showroom
    Book a consultation: On-site, online or in a showroom
  • Your sales contacts
    Your sales contacts
  • Fairs & Congresses
    Fairs & Congresses
  • Contact form
    Contact form
  • Company & Apprenticeship
    Company & Apprenticeship
Book a consultation: On-site, online or in a showroom
Book a consultation: On-site, online or in a showroom
Your sales contacts
Your sales contacts
Fairs & Congresses
Fairs & Congresses
Contact form
Contact form
Company & Apprenticeship
Company & Apprenticeship
Free Webinar: For more hygiene, better instrument protection & clear workflows
Free Webinar: For more hygiene, better instrument protection & clear workflows
Learn more
Identify errors, find solutions: Our Troubleshooting Portal for MELAG products
Identify errors, find solutions: Our Troubleshooting Portal for MELAG products
Start troubleshooting
Free Webinar: For more hygiene, better instrument protection & clear workflows
Free Webinar: For more hygiene, better instrument protection & clear workflows
Learn more
Any questions? We have the answers! Our hygiene experts in Australia will be happy to advise you.
Any questions? We have the answers! Our hygiene experts in Australia will be happy to advise you.
Contact us now
|
Specialties
  • Dental
  • Medical
  • Ophthalmo
  • Hospital
  • Veterinary
  • Podiatry
  • University
Select language and country

Newsletter Subscription

Register for our newsletter and always stay up to date.

Products
  • Instrument Reprocessing
  • Autoclaves
  • Washer-Disinfectors
  • Ultrasonic cleaners
  • Sealing Devices
Service
  • Downloads
  • Troubleshooting
  • Video Tutorials
  • Blog
Company
  • We are MELAG
  • Sustainability
  • History
  • News
  • Contact
  • Instrument Reprocessing
  • Autoclaves
  • Washer-Disinfectors
  • Ultrasonic cleaners
  • Sealing Devices
  • Downloads
  • Troubleshooting
  • Video Tutorials
  • Blog
  • We are MELAG
  • Sustainability
  • History
  • News
  • Contact
  • Imprint
  • Terms and Conditions
  • Privacy
  • Whistleblower
  • Open Cookie Settings

© MELAG Medizintechnik GmbH & Co. KG

Placeholder for alt text
Excellence in prophylaxis & hygiene:

EMS Reprocessing guide 2024

Discover the comprehensive guide to efficient reprocessing of your EMS prophylaxis instruments.

Download reprocessing guide
Arrange a consultation
Step 1

The correct risk classification of your AIRFLOW® Prophylaxis Master handpieces and instruments

With AIRFLOW® handpieces and instruments you can remove the stained biofilm supra- and subgingivally up to 4 mm. In the event of contact with mucous membranes or pathologically altered skin, the English hollow instruments are classified as at least semi-critical category B in accordance with RKI recommendations. Although some treatment steps take place above the gums, dental treatment can quickly move into a critical area. This is mainly due to the frequent bleeding of patients' gums and the easy accessibility of calculus in the gingival pockets or under the gingiva.

To ensure the necessary flexibility in treatment, a thorough process of cleaning, disinfection and packaged sterilization is required. This applies to both the handpiece and the powder jet nozzle, as both parts must be regarded as a single unit when used together.

The components of the PERIOFLOW® treatment, which are used to remove calculus in deep pockets up to 9 mm, on furcations and on implants, are clearly classified as critical category B due to the necessary invasive mode of operation. The handpiece must therefore also be packaged and sterilized. The nozzle for subgingival treatment, on the other hand, is designed by EMS as a single-use product that is replaced after each use and is therefore not reprocessed.

The PIEZON® instrument is used both supragingivally and up to 10 mm subgingivally. The various P, PI, PS or PSR tips used for their invasive and periodontal surgical applications require a complete reprocessing cycle with cleaning, disinfection and packaged sterilization. The correct classification of ZEG or PA tips, which are only used above the gingiva, is somewhat more complex. Although classification as semi-critical B would theoretically be possible, the variable requirements of different patient groups often mean that more extensive reprocessing is necessary. To ensure legal safety, it is advisable to always carry out complete reprocessing including packaged sterilization. Please bear in mind that the risk classification must be carried out by each operator and justified to the authorities. Be on the safe side - your patients, your team and your sleep will thank you!


Step 2

The perfect workflow - tailored to your needs

Modern prophylaxis requires an equally modern preparation workflow. What used to be considered time-consuming and cost-intensive can now be designed to save costs, space and time thanks to advanced technology. Our innovative 4-in-1 Careclave solution combines cleaning, disinfection, care and sterilization in a single device. Thanks to the attachable Carebox, this workflow enables outstanding cleaning and disinfection results for up to 8 transfer instruments, such as prophylaxis handpieces or ZEG tips, in just 16 minutes. Simply place your instruments in the Carebox Green and select the appropriate reprocessing program.

Our versatile 4-in-1 solution adapts flexibly to your needs and offers different program options depending on the load in the chamber. The Care-Therm program enables fast cleaning and disinfection of a fully loaded Carebox Green. However, Careclave complies with both the standard for thermal disinfectors (EN 15883) and for autoclaves (EN 13060). This means you can sterilize up to 8 trays or 4 MELAstore boxes with a total of up to 11 kg of instruments, including wrapped handpieces and ZEG tips, in just one cycle with the Universal B program. For smaller quantities of wrapped instruments, the Care-B Combi program offers the option of efficiently reprocessing them on short trays together with the Carebox Green. These flexible options ensure that your instruments are available quickly and provide you with optimum support in your day-to-day work.

Summary

Safe Reprocessing of EMS Preventive Care Instruments

For the safe reprocessing of EMS prophylaxis instruments, the correct risk classification, appropriate adapters, and a coordinated workflow are crucial:

  • Risk-Based Reprocessing: Reusable AIRFLOW®, PERIOFLOW®, and PIEZON® instruments are cleaned, disinfected, and—if necessary—packaged and sterilized according to their risk classification.

  • Coordinated Adapters and Workflows: Special EMS adapters enable the safe internal cleaning of hollow instruments and support efficient machine-based reprocessing.

  • 4-in-1 reprocessing with Careclave: Careclave combines cleaning, disinfection, maintenance, and sterilization in a single device and, with the Carebox Green, reprocesses up to eight prophylaxis instruments simultaneously.

  • Alternative using a thermal disinfector and autoclave: EMS instruments can first be cleaned, disinfected, and dried in the MELAtherm and then—if necessary—sterilized in a Class B autoclave after being packaged.

  • Rapid Instrument Availability: Coordinated processes and flexible loading options reduce the reprocessing workload and enable instruments to be made available again quickly.

Download reprocessing guide

Publication Date: July 20, 2024

Schedule an appointment now
Siegfried Kontaktbild

Author: Siegfried Weinhart

MELAG x EMS - This is how future works!

State-of-the-art methods for your dental practice.

Guided Biofilm Therapy (GBT) has established itself globally as the state-of-the-art approach for professional tooth cleaning. Treatment with AIRFLOW®, PERIOFLOW® and PIEZON® instruments delivers optimal results in both pain-free scaling and the promotion of general oral health. To maintain the long-term functionality of your valuable EMS instruments, efficient and legally compliant reprocessing is essential. This not only contributes to rapid availability for patients, but also avoids costly downtimes and repair times. In cooperation, MELAG and EMS have developed perfectly coordinated products and an efficient two-step guide to make your dental hygiene workflow as simple and effective as possible.

DISCOVER CARECLAVE NOWEMS AIRFLOW® PROPHYLAXIS MASTER
Balkenanimation-Careclave

Enable YouTube content

To play this video, please allow cookies and other external services from YouTube.

Placeholder for alt text

Support & Contact

You have questions? We the answers!

Arrange a consultationContact our team in Australia To the product finder

Safe reprocessing of your EMS instruments is of course also possible with a combination of thermal disinfector and autoclave. This is because our high-quality EMS adapters also maximize efficiency in the MELAtherm. In the first step, instrument sets for over 45 patients and up to 33 hollow-body instruments are cleaned, disinfected and dried per cycle.

You can install the adapters either directly in the injector rail with Cleanfinity filter or, if a central filter is not used, using a single filter housing (order no. 73905). For optimum convenience, we recommend the Flex 1 injector basket (order no. 80740), which can conveniently reprocess up to six ZEG, ultrasonic or air scaler tips, whereby only two connections are required on the injector rail.

The second step involves the packaged sterilization of the handpieces and the ZEG tips including torque wrench in a B-class autoclave, such as our Premium class.


Enable YouTube content

To play this video, please allow cookies and other external services from YouTube.

As if made for you:

Our EMS adapters for Careclave and MELAtherm

For perfect adaptation without the instruments slipping out, we have developed special adapters for EMS instruments in collaboration with our Swiss friends. These not only hold the instruments securely in place, but also ensure the best possible cleaning and disinfection - and therefore long-term instrument protection:

The adapter is suitable for EMS AIR-FLOW Prophylaxis Master handpieces of type MAX / MAX 2.0 EL-308 (Prophylaxis Master) PERIOFLOW EL-354.

Order no. ME80614

Learn More
ME80614

So there are no questions left!

MELAG and EMS - a strong team for strong dental practices. We offer not only innovative products, but also comprehensive services. If you have any questions or are unsure which solution is best for your practice, no problem! We are there for you 24/7. Contact us via our LiveChat, book a live demo or visit our contact overview page. We look forward to supporting you!


Arrange consultation
live-demo